Package | hl7.fhir.uv.phd |
Type | ValueSet |
Id | Id |
FHIR Version | R4 |
Source | http://hl7.org/fhir/uv/phd/https://build.fhir.org/ig/HL7/phd/ValueSet-DeviceTypes11073MDC.html |
Url | http://hl7.org/fhir/uv/phd/ValueSet/DeviceTypes11073MDC |
Version | 1.1.0 |
Status | active |
Date | 2021-09-25 |
Name | DeviceTypes11073MDC |
Title | Device Type Specialization IEEE 11073-10101 Nomenclature Codes |
Experimental | False |
Realm | uv |
Authority | hl7 |
Description | ValueSet for the ISO/IEEE 11073-10101 Nomenclatures Describing Device specialization types such as blood pressure, pulse oximeter, thermometer, ecg, etc.. Nomenclature codes are 32-bit numbers where the upper 16 bits represent the partition and the lower 16 bits represent the term code. Most of the codes included in this value set are from partition infra which has value 8. THe 32-bit code for the pulse oximeter, which has term code 4100 in partition infra, is given by 524288 + 4100 = 528388. This value set will grow as new specializations are defined. The display value consists of the nomenclature code's reference identifier. Devices exchange the numerical codes in the IEEE 11073 communication standards, not reference identifiers, but the reference identifiers are often used where human readability are more important than efficiency or bandwidth. However, only the numerical codes are guaranteed to be unique. |
No resources found
CodeSystem | |
urn:iso:std:iso:11073:10101 | ISO 11073-10101 Health informatics - Point-of-care |
Note: links and images are rebased to the (stated) source
Generated Narrative: ValueSet DeviceTypes11073MDC
urn:iso:std:iso:11073:10101
Code | Display |
528388 | MDC_DEV_SPEC_PROFILE_PULS_OXIM: Pulse oximeter |
528390 | MDC_DEV_SPEC_PROFILE_MIN_ECG: Electrocardiogram (ECG) |
528391 | MDC_DEV_SPEC_PROFILE_BP: Non-invasive Blood Pressure monitor |
528392 | MDC_DEV_SPEC_PROFILE_TEMP : Thermometer |
528397 | MDC_DEV_SPEC_PROFILE_RESP_RATE : Respiration rate monitor |
528399 | MDC_DEV_SPEC_PROFILE_SCALE : Weight scale |
528401 | MDC_DEV_SPEC_PROFILE_GLUCOSE: Glucose monitor |
528402 | MDC_DEV_SPEC_PROFILE_COAG: Coagulation meter |
528403 | MDC_DEV_SPEC_PROFILE_INSULIN_PUMP: Insulin pump |
528404 | MDC_DEV_SPEC_PROFILE_BCA: Body composition analyzer |
528405 | MDC_DEV_SPEC_PROFILE_BCA: Peak Flow meter |
528406 | MDC_DEV_SPEC_PROFILE_URINE: Urine analyzer |
528408 | MDC_DEV_SPEC_PROFILE_SABTE: Sleep Apnea and Breathing Therapy Equipment |
528409 | MDC_DEV_SPEC_PROFILE_CGM: Continuous Glucose Monitor |
528412 | MDC_DEV_SPEC_PROFILE_PSM: Power Status Monitor |
528413 | MDC_DEV_SPEC_PROFILE_SPIRO: Spirometer |
528425 | MDC_DEV_SPEC_PROFILE_HF_CARDIO: Cardiovascular exercise equipment |
528426 | MDC_DEV_SPEC_PROFILE_HF_STRENGH: Strength and fitness equipment |
528455 | MDC_DEV_SPEC_PROFILE_AI_ACTIVITY_HUB: Independent living hub |
528456 | MDC_DEV_SPEC_PROFILE_AI_NED_MINDER: Medication Monitor |
528457 | MDC_DEV_SPEC_PROFILE_GENERIC: Device following the IEEE 11073-10206 standard but no specific specialization |
528484 | MDC_DEV_SUB_SPEC_PROFILE_STEP_COUNTER: Step counter |
528501 | MDC_DEV_SUB_SPEC_PROFILE_FALL_SENSOR: Fall sensor |
528502 | MDC_DEV_SUB_SPEC_PROFILE_PERS_SENSOR: Personal sensor |
528503 | MDC_DEV_SUB_SPEC_PROFILE_SMOKE_SENSOR: Smoke sensor |
528504 | MDC_DEV_SUB_SPEC_PROFILE_CO_SENSOR: Carbon Monoxide sensor |
528505 | MDC_DEV_SUB_SPEC_PROFILE_WATER_SENSOR: Water sensor |
528506 | MDC_DEV_SUB_SPEC_PROFILE_GAS_SENSOR: Gas sensor |
528507 | MDC_DEV_SUB_SPEC_PROFILE_MOTION_SENSOR: Motion sensor |
528508 | MDC_DEV_SUB_SPEC_PROFILE_PROPEXIT_SENSOR: Property Exit sensor |
528509 | MDC_DEV_SUB_SPEC_PROFILE_ENURESIS_SENSOR: Enuresis sensor |
528510 | MDC_DEV_SUB_SPEC_PROFILE_CONTACTCLOSURE_SENSOR: Contact Closure sensor |
528511 | MDC_DEV_SUB_SPEC_PROFILE_USAGE_SENSOR: Usage sensor |
528512 | MDC_DEV_SUB_SPEC_PROFILE_SWITCH_SENSOR: Switch sensor |
528513 | MDC_DEV_SUB_SPEC_PROFILE_DOSAGE_SENSOR: Dosage sensor |
528514 | MDC_DEV_SUB_SPEC_PROFILE_TEMP_SENSOR: Temperature sensor |
528524 | MDC_DEV_SUB_SPEC_PROFILE_ECG: ECG supporting waveforms |
528525 | MDC_DEV_SUB_SPEC_PROFILE_HR: ECG supporting just heart rate |
528532 | MDC_DEV_SUB_SPEC_PROFILE_CPAP: Specialized SABTE device providing CPAP (continuous positive airway pressure) manually set |
528533 | MDC_DEV_SUB_SPEC_PROFILE_CPAP_AUTO: Specialized SABTE device providing CPAP (continuous positive airway pressure) automatically |
528534 | MDC_DEV_SUB_SPEC_PROFILE_BPAP: Specialized SABTE device providing BPAP (Bi-level positive airway pressure) manually set |
528535 | MDC_DEV_SUB_SPEC_PROFILE_BPAP_AUTO: Specialized SABTE device providing BPAP (Bi-level positive airway pressure) automatically |
528536 | MDC_DEV_SUB_SPEC_PROFILE_ACSV: Specialized SABTE device providing ACSV (Anti-cyclic Servo Ventilation) |
{
"resourceType" : "ValueSet",
"id" : "DeviceTypes11073MDC",
"meta" : {
"profile" : [
"http://hl7.org/fhir/StructureDefinition/shareablevalueset"
]
},
"text" : {
"status" : "generated",
"div" : "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p class=\"res-header-id\"><b>Generated Narrative: ValueSet DeviceTypes11073MDC</b></p><a name=\"DeviceTypes11073MDC\"> </a><a name=\"hcDeviceTypes11073MDC\"> </a><a name=\"DeviceTypes11073MDC-en-US\"> </a><ul><li>Include these codes as defined in <a href=\"http://terminology.hl7.org/6.0.2/CodeSystem-v3-mdc.html\"><code>urn:iso:std:iso:11073:10101</code></a><table class=\"none\"><tr><td style=\"white-space:nowrap\"><b>Code</b></td><td><b>Display</b></td></tr><tr><td>528388</td><td>MDC_DEV_SPEC_PROFILE_PULS_OXIM: Pulse oximeter</td></tr><tr><td>528390</td><td>MDC_DEV_SPEC_PROFILE_MIN_ECG: Electrocardiogram (ECG)</td></tr><tr><td>528391</td><td>MDC_DEV_SPEC_PROFILE_BP: Non-invasive Blood Pressure monitor</td></tr><tr><td>528392</td><td>MDC_DEV_SPEC_PROFILE_TEMP : Thermometer</td></tr><tr><td>528397</td><td>MDC_DEV_SPEC_PROFILE_RESP_RATE : Respiration rate monitor</td></tr><tr><td>528399</td><td>MDC_DEV_SPEC_PROFILE_SCALE : Weight scale</td></tr><tr><td>528401</td><td>MDC_DEV_SPEC_PROFILE_GLUCOSE: Glucose monitor</td></tr><tr><td>528402</td><td>MDC_DEV_SPEC_PROFILE_COAG: Coagulation meter</td></tr><tr><td>528403</td><td>MDC_DEV_SPEC_PROFILE_INSULIN_PUMP: Insulin pump</td></tr><tr><td>528404</td><td>MDC_DEV_SPEC_PROFILE_BCA: Body composition analyzer</td></tr><tr><td>528405</td><td>MDC_DEV_SPEC_PROFILE_BCA: Peak Flow meter</td></tr><tr><td>528406</td><td>MDC_DEV_SPEC_PROFILE_URINE: Urine analyzer</td></tr><tr><td>528408</td><td>MDC_DEV_SPEC_PROFILE_SABTE: Sleep Apnea and Breathing Therapy Equipment</td></tr><tr><td>528409</td><td>MDC_DEV_SPEC_PROFILE_CGM: Continuous Glucose Monitor</td></tr><tr><td>528412</td><td>MDC_DEV_SPEC_PROFILE_PSM: Power Status Monitor</td></tr><tr><td>528413</td><td>MDC_DEV_SPEC_PROFILE_SPIRO: Spirometer</td></tr><tr><td>528425</td><td>MDC_DEV_SPEC_PROFILE_HF_CARDIO: Cardiovascular exercise equipment</td></tr><tr><td>528426</td><td>MDC_DEV_SPEC_PROFILE_HF_STRENGH: Strength and fitness equipment</td></tr><tr><td>528455</td><td>MDC_DEV_SPEC_PROFILE_AI_ACTIVITY_HUB: Independent living hub</td></tr><tr><td>528456</td><td>MDC_DEV_SPEC_PROFILE_AI_NED_MINDER: Medication Monitor</td></tr><tr><td>528457</td><td>MDC_DEV_SPEC_PROFILE_GENERIC: Device following the IEEE 11073-10206 standard but no specific specialization</td></tr><tr><td>528484</td><td>MDC_DEV_SUB_SPEC_PROFILE_STEP_COUNTER: Step counter</td></tr><tr><td>528501</td><td>MDC_DEV_SUB_SPEC_PROFILE_FALL_SENSOR: Fall sensor</td></tr><tr><td>528502</td><td>MDC_DEV_SUB_SPEC_PROFILE_PERS_SENSOR: Personal sensor</td></tr><tr><td>528503</td><td>MDC_DEV_SUB_SPEC_PROFILE_SMOKE_SENSOR: Smoke sensor</td></tr><tr><td>528504</td><td>MDC_DEV_SUB_SPEC_PROFILE_CO_SENSOR: Carbon Monoxide sensor</td></tr><tr><td>528505</td><td>MDC_DEV_SUB_SPEC_PROFILE_WATER_SENSOR: Water sensor</td></tr><tr><td>528506</td><td>MDC_DEV_SUB_SPEC_PROFILE_GAS_SENSOR: Gas sensor</td></tr><tr><td>528507</td><td>MDC_DEV_SUB_SPEC_PROFILE_MOTION_SENSOR: Motion sensor</td></tr><tr><td>528508</td><td>MDC_DEV_SUB_SPEC_PROFILE_PROPEXIT_SENSOR: Property Exit sensor</td></tr><tr><td>528509</td><td>MDC_DEV_SUB_SPEC_PROFILE_ENURESIS_SENSOR: Enuresis sensor</td></tr><tr><td>528510</td><td>MDC_DEV_SUB_SPEC_PROFILE_CONTACTCLOSURE_SENSOR: Contact Closure sensor</td></tr><tr><td>528511</td><td>MDC_DEV_SUB_SPEC_PROFILE_USAGE_SENSOR: Usage sensor</td></tr><tr><td>528512</td><td>MDC_DEV_SUB_SPEC_PROFILE_SWITCH_SENSOR: Switch sensor</td></tr><tr><td>528513</td><td>MDC_DEV_SUB_SPEC_PROFILE_DOSAGE_SENSOR: Dosage sensor</td></tr><tr><td>528514</td><td>MDC_DEV_SUB_SPEC_PROFILE_TEMP_SENSOR: Temperature sensor</td></tr><tr><td>528524</td><td>MDC_DEV_SUB_SPEC_PROFILE_ECG: ECG supporting waveforms</td></tr><tr><td>528525</td><td>MDC_DEV_SUB_SPEC_PROFILE_HR: ECG supporting just heart rate</td></tr><tr><td>528532</td><td>MDC_DEV_SUB_SPEC_PROFILE_CPAP: Specialized SABTE device providing CPAP (continuous positive airway pressure) manually set</td></tr><tr><td>528533</td><td>MDC_DEV_SUB_SPEC_PROFILE_CPAP_AUTO: Specialized SABTE device providing CPAP (continuous positive airway pressure) automatically</td></tr><tr><td>528534</td><td>MDC_DEV_SUB_SPEC_PROFILE_BPAP: Specialized SABTE device providing BPAP (Bi-level positive airway pressure) manually set</td></tr><tr><td>528535</td><td>MDC_DEV_SUB_SPEC_PROFILE_BPAP_AUTO: Specialized SABTE device providing BPAP (Bi-level positive airway pressure) automatically</td></tr><tr><td>528536</td><td>MDC_DEV_SUB_SPEC_PROFILE_ACSV: Specialized SABTE device providing ACSV (Anti-cyclic Servo Ventilation)</td></tr></table></li></ul></div>"
},
"extension" : [
{
"url" : "http://hl7.org/fhir/StructureDefinition/structuredefinition-wg",
"valueCode" : "dev"
}
],
"url" : "http://hl7.org/fhir/uv/phd/ValueSet/DeviceTypes11073MDC",
"version" : "1.1.0",
"name" : "DeviceTypes11073MDC",
"title" : "Device Type Specialization IEEE 11073-10101 Nomenclature Codes",
"status" : "active",
"experimental" : false,
"date" : "2021-09-25",
"publisher" : "HL7 International / Health Care Devices",
"contact" : [
{
"telecom" : [
{
"system" : "url",
"value" : "http://www.hl7.org/Special/committees/healthcaredevices"
}
]
}
],
"description" : "ValueSet for the ISO/IEEE 11073-10101 Nomenclatures Describing Device specialization types such as blood pressure, pulse oximeter, thermometer, ecg, etc.. Nomenclature codes are 32-bit numbers where the upper 16 bits represent the partition and the lower 16 bits represent the term code. Most of the codes included in this value set are from partition infra which has value 8. THe 32-bit code for the pulse oximeter, which has term code 4100 in partition infra, is given by 524288 + 4100 = 528388. This value set will grow as new specializations are defined. The display value consists of the nomenclature code's reference identifier. Devices exchange the numerical codes in the IEEE 11073 communication standards, not reference identifiers, but the reference identifiers are often used where human readability are more important than efficiency or bandwidth. However, only the numerical codes are guaranteed to be unique.",
"jurisdiction" : [
{
"coding" : [
{
"system" : "http://unstats.un.org/unsd/methods/m49/m49.htm",
"code" : "001"
}
]
}
],
"compose" : {
"include" : [
{
"system" : "urn:iso:std:iso:11073:10101",
"concept" : [
{
"code" : "528388",
"display" : "MDC_DEV_SPEC_PROFILE_PULS_OXIM: Pulse oximeter"
},
{
"code" : "528390",
"display" : "MDC_DEV_SPEC_PROFILE_MIN_ECG: Electrocardiogram (ECG)"
},
{
"code" : "528391",
"display" : "MDC_DEV_SPEC_PROFILE_BP: Non-invasive Blood Pressure monitor"
},
{
"code" : "528392",
"display" : "MDC_DEV_SPEC_PROFILE_TEMP : Thermometer"
},
{
"code" : "528397",
"display" : "MDC_DEV_SPEC_PROFILE_RESP_RATE : Respiration rate monitor"
},
{
"code" : "528399",
"display" : "MDC_DEV_SPEC_PROFILE_SCALE : Weight scale"
},
{
"code" : "528401",
"display" : "MDC_DEV_SPEC_PROFILE_GLUCOSE: Glucose monitor"
},
{
"code" : "528402",
"display" : "MDC_DEV_SPEC_PROFILE_COAG: Coagulation meter"
},
{
"code" : "528403",
"display" : "MDC_DEV_SPEC_PROFILE_INSULIN_PUMP: Insulin pump"
},
{
"code" : "528404",
"display" : "MDC_DEV_SPEC_PROFILE_BCA: Body composition analyzer"
},
{
"code" : "528405",
"display" : "MDC_DEV_SPEC_PROFILE_BCA: Peak Flow meter"
},
{
"code" : "528406",
"display" : "MDC_DEV_SPEC_PROFILE_URINE: Urine analyzer"
},
{
"code" : "528408",
"display" : "MDC_DEV_SPEC_PROFILE_SABTE: Sleep Apnea and Breathing Therapy Equipment"
},
{
"code" : "528409",
"display" : "MDC_DEV_SPEC_PROFILE_CGM: Continuous Glucose Monitor"
},
{
"code" : "528412",
"display" : "MDC_DEV_SPEC_PROFILE_PSM: Power Status Monitor"
},
{
"code" : "528413",
"display" : "MDC_DEV_SPEC_PROFILE_SPIRO: Spirometer"
},
{
"code" : "528425",
"display" : "MDC_DEV_SPEC_PROFILE_HF_CARDIO: Cardiovascular exercise equipment"
},
{
"code" : "528426",
"display" : "MDC_DEV_SPEC_PROFILE_HF_STRENGH: Strength and fitness equipment"
},
{
"code" : "528455",
"display" : "MDC_DEV_SPEC_PROFILE_AI_ACTIVITY_HUB: Independent living hub"
},
{
"code" : "528456",
"display" : "MDC_DEV_SPEC_PROFILE_AI_NED_MINDER: Medication Monitor"
},
{
"code" : "528457",
"display" : "MDC_DEV_SPEC_PROFILE_GENERIC: Device following the IEEE 11073-10206 standard but no specific specialization"
},
{
"code" : "528484",
"display" : "MDC_DEV_SUB_SPEC_PROFILE_STEP_COUNTER: Step counter"
},
{
"code" : "528501",
"display" : "MDC_DEV_SUB_SPEC_PROFILE_FALL_SENSOR: Fall sensor"
},
{
"code" : "528502",
"display" : "MDC_DEV_SUB_SPEC_PROFILE_PERS_SENSOR: Personal sensor"
},
{
"code" : "528503",
"display" : "MDC_DEV_SUB_SPEC_PROFILE_SMOKE_SENSOR: Smoke sensor"
},
{
"code" : "528504",
"display" : "MDC_DEV_SUB_SPEC_PROFILE_CO_SENSOR: Carbon Monoxide sensor"
},
{
"code" : "528505",
"display" : "MDC_DEV_SUB_SPEC_PROFILE_WATER_SENSOR: Water sensor"
},
{
"code" : "528506",
"display" : "MDC_DEV_SUB_SPEC_PROFILE_GAS_SENSOR: Gas sensor"
},
{
"code" : "528507",
"display" : "MDC_DEV_SUB_SPEC_PROFILE_MOTION_SENSOR: Motion sensor"
},
{
"code" : "528508",
"display" : "MDC_DEV_SUB_SPEC_PROFILE_PROPEXIT_SENSOR: Property Exit sensor"
},
{
"code" : "528509",
"display" : "MDC_DEV_SUB_SPEC_PROFILE_ENURESIS_SENSOR: Enuresis sensor"
},
{
"code" : "528510",
"display" : "MDC_DEV_SUB_SPEC_PROFILE_CONTACTCLOSURE_SENSOR: Contact Closure sensor"
},
{
"code" : "528511",
"display" : "MDC_DEV_SUB_SPEC_PROFILE_USAGE_SENSOR: Usage sensor"
},
{
"code" : "528512",
"display" : "MDC_DEV_SUB_SPEC_PROFILE_SWITCH_SENSOR: Switch sensor"
},
{
"code" : "528513",
"display" : "MDC_DEV_SUB_SPEC_PROFILE_DOSAGE_SENSOR: Dosage sensor"
},
{
"code" : "528514",
"display" : "MDC_DEV_SUB_SPEC_PROFILE_TEMP_SENSOR: Temperature sensor"
},
{
"code" : "528524",
"display" : "MDC_DEV_SUB_SPEC_PROFILE_ECG: ECG supporting waveforms"
},
{
"code" : "528525",
"display" : "MDC_DEV_SUB_SPEC_PROFILE_HR: ECG supporting just heart rate"
},
{
"code" : "528532",
"display" : "MDC_DEV_SUB_SPEC_PROFILE_CPAP: Specialized SABTE device providing CPAP (continuous positive airway pressure) manually set"
},
{
"code" : "528533",
"display" : "MDC_DEV_SUB_SPEC_PROFILE_CPAP_AUTO: Specialized SABTE device providing CPAP (continuous positive airway pressure) automatically"
},
{
"code" : "528534",
"display" : "MDC_DEV_SUB_SPEC_PROFILE_BPAP: Specialized SABTE device providing BPAP (Bi-level positive airway pressure) manually set"
},
{
"code" : "528535",
"display" : "MDC_DEV_SUB_SPEC_PROFILE_BPAP_AUTO: Specialized SABTE device providing BPAP (Bi-level positive airway pressure) automatically"
},
{
"code" : "528536",
"display" : "MDC_DEV_SUB_SPEC_PROFILE_ACSV: Specialized SABTE device providing ACSV (Anti-cyclic Servo Ventilation)"
}
]
}
]
}
}
XIG built as of ??metadata-date??. Found ??metadata-resources?? resources in ??metadata-packages?? packages.